Labour Day - Special 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 70dumps

H19-371_V1.0 Questions and Answers

Question # 6

UPS2000-G 1~3kVA supports () parallel.

A.

0

B.

2

C.

3

D.

4

Full Access
Question # 7

The type of humidifier adopted by the row-level chilled water intelligent temperature control product NetCol5000-C032H is ( )

A.

Electrodes

B.

Infrared

C.

Wet film

D.

Ultrasound

Full Access
Question # 8

Which of the following tasks does the work of data center operation and maintenance include? (multiple choice)

A.

Real-time monitoring

B.

Routine Maintenance

C.

Major overhaul

D.

Emergency drills

Full Access
Question # 9

What type of equipment room is physically isolated in the power distribution room (multiple choice)

A.

Class A

B.

Class B

C.

Class C

D.

Tier IV

Full Access
Question # 10

The environmental parameters of the data center host room are: ( ).

A.

Temperature 18~27C

B.

Dew point temperature 5.5~ 15C .

C.

The relative humidity is not more than 60%.

D.

No condensation in the computer room

E.

Satisfy both ABCD.

Full Access
Question # 11

The UPS supports a variety of systems to meet customer application grid scenarios. Which systems does the UPS2000-G 15/20KVA model support? ( )

A.

Single in, single out

B.

One in three out

C.

Three in and three out

D.

Three in and one out

Full Access
Question # 12

Regarding the Fusionlodule2000 wiring, which of the following statements is wrong?

A.

Cross-channel routing is through the control skylight

B.

The wiring trough supports the separation of strong and weak electricity

C.

The power distribution cabinet/integrated UPS can not be placed at the head of the column

D.

Cross-channel routing requires installation of cable ladders

Full Access
Question # 13

Which core differentiated features of FusionModule800 can shield opponents? ( ).

A.

Rack-mounted inverter air conditioner

B.

Integrated design of cold and electric control.

C.

Light-load dehumidification of air conditioners

D.

ibattery.

Full Access
Question # 14

FusionModule1000A V2R3 version prefabricated integrated data center has Najishen solution (multiple choice)

A.

20 feet IT solution

B.

20-foot CT Solution

C.

40 feet IT solution

D.

40-foot CT Solution

E.

40 feet ICT solution

Full Access
Question # 15

UPS5000-E about the characteristics of intelligence, which are correct? ()

A.

Support NetEco monitoring software, support centralized monitoring of UPS

B.

Support battery intelligent management, effectively prolong battery life

C.

The NetEco monitoring software of UPS5000-A supports SMS or E-mail remote alarm.

Full Access
Question # 16

Using UPS5000-E (50kVA power module), the actual load is 160kW, the rack 1+1 redundancy, the single-machine backup power scheme is adopted, the backup power scheme for each machine, each rack has 3

sets of batteries, each set of 40 cells, The main switch box capacity is (

A.

630A

B.

500A

C.

250A

D.

320A

Full Access
Question # 17

UPS5000-series modular UPS product features are similar to which of the following product models? ( )

A.

Hipulse-u

B.

80-NET

C.

NXr

D.

APM

Full Access
Question # 18

What kinds of pillar-clad scenes are there in FM2000? ().

A.

Column in channel

B.

The column is in the cabinet.

C.

Columns span cabinets and aisles

D.

Columns at both ends of the cabinet

Full Access
Question # 19

UPS5000-E-500K Regarding efficiency, which of the following options is correct? ()

A.

Efficiency 96%

B.

Efficiency 94%

C.

ECO mode 99%

D.

ECO mode 98%

Full Access
Question # 20

The asset management module of the NetEco management system supports which of the following parameters can be used to quickly search for asset information? (Multiple choice)

A.

Name

B.

Location

C.

Type

D.

Status

Full Access
Question # 21

When using ModBUS to remotely manage the UPS500-E, which option should be selected? ( )

A.

not required

B.

RS232 to USB interface

C.

ModBUS card

Full Access
Question # 22

Which of the following are the main features of the UPS2000-G-(6K-20K) PDU?

A.

Realize the input and output power distribution of two parallel machines

B.

Provide single or parallel system centralized maintenance bypass

C.

Extended output socket: OT: 4*C13; 2*C19

D.

Provide surrounding environment monitoring and alarm

Full Access
Question # 23

NetCol5000-A042H Full-cabinet row-level air-cooled inverter precision air conditioner can match the outdoor unit model and adaptable temperature range: ()/

A.

NetCol500-A026 (-20~45℃)

B.

NetCol500-A036 (-40~45℃ need to bring low temperature components)

C.

NetCol500-A072 (-5~55℃)

D.

NetCol500-A088 (-5-55℃)

Full Access
Question # 24

What is the lightning protection level of the integrated UPS of FusionModule2000?

A.

B-level lightning protection

B.

Class C lightning protection

C.

Class A lightning protection

Full Access
Question # 25

The cell of Huawei Smartli lithium battery is ()

A.

NCM

B.

LFP

C.

Ni-Cd

Full Access
Question # 26

When the operating temperature of the UPS2000-A is too high ().

A.

Switch to bypass mode

B.

Switch battery mode

C.

Stop output, load power off

D.

no action

Full Access
Question # 27

The NetEco6000 management system can manage the devices inside the FusionModule and outside the module at the same time. In the default recommended solution, the

devices inside the FusionModule use the ( ) collector to access the device, and the devices outside the module use the ( ) collector. to access the device?

A.

ECC500, ECC500

B.

ECC500, ECC800

C.

ECC800, ECC500

D.

ECC800, ECC800

Full Access
Question # 28

The NetEco6000 management system supports access to third-party equipment to achieve centralized management of the computer room; then, when monitoring which of the following equipment is connected to third-party equipment,

it is necessary to pay the RM bill and report the third-party equipment access fee? (

A.

Huawei UPS 5000E

B.

Huawei Power Supply TP48300

C.

Emerson Air Conditioning

D.

None of the above is true

Full Access
Question # 29

The output power factor of UPS5000-E is as high as ( ), which can carry 11% more load than traditional UPS.

A.

1

B.

0.9

C.

0.95.

Full Access
Question # 30

UPS2000-A-(1K-3K) output power factor is ().

A.

0.7

B.

0.8

C.

0.9

D.

0.99

Full Access
Question # 31

UPS2000-G 6-20k host operation interface is (), which can display system status in real time ( )

A.

LED

B.

LCD

C.

touch screen

D.

Remote network management.

Full Access
Question # 32

Regarding the cabinet rPDU of Fusionmodule2000, which of the following statements is wrong? ( )

A.

There are half height and full height

B.

Support C13 and C19 and national standard sockets

C.

Smart rPDU supports remote monitoring, but does not support remote

shutdown.

Full Access
Question # 33

NetEco. supports northbound integration, which of the following is not currently supported? ( ).

A.

SNMP

B.

Webservice

C.

Modbus

D.

FTP

Full Access
Question # 34

For the UPS5000-A system, which of the following battery configurations is unreasonable: () (multiple choice)

A.

32 12V batteries

B.

37 12V batteries

C.

40 12V batteries

D.

42 12V batteries

Full Access
Question # 35

When the Netfco management system adopts the single 6RH1585 server, it can support the maximum access (10,000 test points, so as to realize the centralized management of multiple data centers?

A.

20

B.

40

C.

50

D.

100

Full Access
Question # 36

In the FusionModule2000 configurator, what are the common cabinet specifications (

A.

600*1200*2000

B.

800*1200*2000

C.

600*1200*2200

D.

800*1200*2200

Full Access
Question # 37

The NetEco management system combines the operation and maintenance experience of Huawei I and the process department to launch an electronic remote maintenance module to help the operation and maintenance personnel to complete the daily operation and inspection of the computer room. Which of the following functions can be achieved: (multiple choice)

A.

Support the formulation of inspection plans, track inspection progress,

B.

Support custom documents for inspection content and inspection routes

C.

With the help of mobile App, you can receive inspection tasks and record the inspection process in vain

D.

Support the generation of road inspection reports in the computer room

Full Access
Question # 38

The new room-level air-cooled series can support -40C applications with optional low-temperature components ( )

A.

True

B.

False

Full Access
Question # 39

2GUPSS000-E (50kVA power module) 150kVA, rack 1+1 redundancy, total input power distribution cabinet, the required total input switch is ( ). /

A.

250A

B.

320A

C.

500A

D.

630A

Full Access
Question # 40

The Huawei Configurator can automatically configure the cable specifications and lengths from the head cabinet to the IT cabinet. ( ).

A.

True

B.

False

Full Access
Question # 41

UPS5000-E can easily realize N+X power supply system by only selecting ( ) , and the operation is simple and convenient. .

A.

BSC cable

B.

Parallel cable

C.

BSC Control Board

D.

Parallel card

Full Access
Question # 42

UPS5000-E comes standard with an LCD display, supports multiple languages, can display the system running status in real time, and can store up to ( ) alarm records

A.

2000

B.

2500

C.

3000

Full Access
Question # 43

PDU8000 precision power distribution cabinet supports monitoring of branch circuit phase current, active power, electric energy and branch circuit switch status.

A.

True

B.

False

Full Access
Question # 44

The name of the controller that controls the sunroof in Fusionmodule2000 is ( )

A.

AC actuator

B.

Access Control Actuator

C.

Sunroof Actuator

Full Access
Question # 45

UPS5000-E 100KVA, the input switch to be selected by the machine, which of the following is the most suitable ( )

A.

80A

B.

125A

C.

160A

D.

200A

Full Access
Question # 46

UPS2000-G adopts high power density design, 6k/10k is only 2U high, 15K/20K is only 3U high, reducing installation space.

A.

True

B.

False

Full Access
Question # 47

The controller (ECC800) of Fusionmodule2000 can be linked with the building fire protection system ( )

A.

True

B.

False

Full Access
Question # 48

In a single cabinet configuration scenario, which of the following scenarios can be configured? (

A.

Fusionlodule2000

B.

FusionModule800

C.

FusionModule5000

D.

Fusionlodule500

Full Access
Question # 49

FusionModule800 3.0 closed channel hot and cold channels are optional ()

A.

True

B.

False

Full Access
Question # 50

FusionModule2000 does not support the configuration of sliding doors/electric doors in a single-row cabinet scenario

A.

True

B.

False

Full Access
Question # 51

Fusionlodule500 uses natural heat dissipation (

A.

True

B.

False

Full Access
Question # 52

What certifications do Huawei precision column cabinets have (multiple choice)

A.

Earthquake resistance

B.

CE

C.

UL

D.

Thiel

Full Access
Question # 53

UPS5000-E is a high-efficiency UPS. Which of the following statements is correct? () (multiple choice)

A.

Efficiency up to 96%

B.

The efficiency can reach 95% with 20% load

C.

The efficiency can reach 94% with 20% load

D.

The efficiency can reach 96% with 40% load.

Full Access
Question # 54

NetEco6000 management system uses the above security mechanisms to ensure network security and prevent the leakage of business sensitive data? (multiple choice)

A.

Permission Control

B.

Transmission Security

C.

Storage Security

D.

None of the above is true

Full Access
Question # 55

What are the three-in-one access control methods of Fusionmodule2000 ( )

A.

Password

B.

Fingerprints

C.

Swipe your card

Full Access
Question # 56

The asset management module of the NetEco management system can manage the equipment in the computer room: Which of the following equipment does not belong to the management scope of the NetEco asset management module?

a. server

B. Storage Devices

C. router

D. Office computer

Full Access
Question # 57

UPS5000-E has a wide voltage and frequency input range, which can adapt to harsh grid environment and prolong battery life. What is the input voltage range of UPS5000-E

with load? ( )

A.

305-485V

B.

105-485V

C.

138-485V4

Full Access
Question # 58

When a system is configured with 1H battery backup time, the discharge termination voltage of the battery cell should be selected as ( ).

A.

1.60V

B.

1.67V

C.

1.75V

D.

1.80V

Full Access
Question # 59

One card of UPS2000-G monitors the entire parallel system, and the parallel system only needs one communication option card to monitor the entire parallel system

A.

True

B.

False

Full Access
Question # 60

The intelligent busway can replace the precision configuration cabinet and increase the number of IT cabinets

A.

True

B.

False

Full Access
Question # 61

According to the ICT Research 2018 statistical report, the market share of Huawei's line-level temperature control products in China in 2017 is: ()

A.

First

B.

Second

C.

third

D.

Fourth

Full Access
Question # 62

Which of the following functions or components does the UPS6000-E (50kVA power module) come standard with? ( )

A.

Dry contact communication card

B.

Parallel function

C.

SNMP function

D.

Bus synchronization control function

Full Access
Question # 63

The fan control modes supported by the NetCo18000-C series room-level chilled water intelligent cooling products are ( ).

A.

Return air control

B.

Pressure Control

C.

Mixed air control

D.

Differential pressure control

E.

Supply air control

Full Access
Question # 64

Why are FusionModule500&FusionModule800 generally recommended to customers for typical configuration solutions? (Multiple choices)

A.

The existing typical configuration scheme can basically cover most of the small computer room usage scenarios

B.

The typical configuration solution has a shorter lead time than the customized solution

C.

Typical configuration solutions are better than customized solutions

D.

Typical solutions are more competitive

Full Access
Question # 65

FusionMoudle2000 supports the following cladding scenarios ()

A.

The column is located in the channel

B.

Column spanning aisle and column

C.

The column is located at the head or tail of the column

D.

Columns are located between columns

Full Access
Question # 66

When competing with friends, which of the following statements is correct? ( ).

A.

Schneider can implement CPU-level energy consumption monitoring, but CPU energy consumption does not represent the energy consumption of the entire device, and monitoring is of little significance. Huawei can monitor the energy consumption of each device through rPDU, but does not monitor the CPU energy consumption.

B.

Schneider uses CFD simulation to monitor the temperature, but the CFD software simulation technology used by Schneider is used to predict incompressible fluids. It is more accurate only when the pressure difference is less than 5%. It is not

suitable for data centers. The temperature provided by Huawei Cloud map is more accurate and real-time

C.

The digital operation and maintenance of Schneider and Vertiv are both advantages. Huawei NetEco applies intelligent operation to defend against competition.

D.

Compared with other competitors in the same industry, Huawei's network security and AI energy saving are

advantages.

Full Access
Question # 67

What is the height of the FusionModule2000 cabinet in mm? ( )

A.

2000

B.

2200

C.

1500

D.

3000

Full Access
Question # 68

When the outdoor temperature will be lower than () ℃, the outdoor unit of the air-cooled air conditioner needs to be equipped with low temperature components. ()

A.

-10

B.

-20

C.

-15

D.

-25

Full Access
Question # 69

NETECO Which are the basic functions of the software and do not require separate and customer quotations ( ).

A.

GIS maps

B.

Battery Management

C.

Energy Efficiency Management

D.

Work Order Management

Full Access
Question # 70

The control sunroof of Fusionmodule2000 cannot be flipped open ( )

A.

True

B.

False

Full Access
Question # 71

FusionModule1000A V2R3 version 20-foot CT solution supports a maximum CT load of 8kW /

A.

True

B.

False

Full Access
Question # 72

UPS5000-E without built-in transformer

A.

True

B.

False

Full Access
Question # 73

UPS products such as APM and NR need to be derated at 30 degrees, UPS5000-E does not need to be under 40 degrees ()

A.

True

B.

False

Full Access
Question # 74

The minimum floor height of the computer room required by FusionModule2000 is 2.6 meters.

A.

True

B.

False

Full Access
Question # 75

NecC00024 year-round strong air-cooled variable-standard precision air conditioner has the function of light education dehumidification, which can meet the reliable dehumidification under the minimum 10% negative number, and avoid the condensation in the low-load and

high-humidity environment.

A.

True

B.

False

Full Access
Question # 76

The UPS5000-S power module has a capacity of 50kVA and a height of 2U, the highest power density in the industry.

A.

True

B.

False

Full Access
Question # 77

The battery can meet customer needs regardless of the brand, as long as it depends on the capacity. ( ).

A.

True

B.

False

Full Access
Question # 78

Air conditioning water systems include cooling water systems, chilled water systems and condensate water systems.

A.

True

B.

False

Full Access
Question # 79

NetCo18000-A013U 13kW small cooling capacity temperature control product adopts DC inverter compressor ( )

A.

True

B.

False

Full Access
Question # 80

Each cooling section of the new room-level air-cooled series has two configurations of upper and lower air supply ()

A.

True

B.

False

Full Access
Question # 81

Generally, the backup time of UPS system is less than 30min. It is reasonable to use the constant current method to calculate the battery capacity.

A.

True

B.

False

Full Access
Question # 82

UPS5000-E (50kVA module) supports the adjustable number of battery cells to avoid the replacement of a whole battery caused by a single battery failure and solve the problem of difficult maintenance of

traditional UPS batteries. The adjustable range is 30~44 cells ( ).

A.

True

B.

False

Full Access
Question # 83

Each jack of rPDU in FM2000 supports independent switch ( ).

A.

True

B.

False

Full Access
Question # 84

Huawei precision air conditioners have power over-voltage, under-voltage alarm and fault diagnosis alarm record functions, automatic protection, automatic recovery, automatic restart and other functions.

A.

True

B.

False

Full Access
Question # 85

Three-proof paint coating can significantly reduce the failure rate of UPS in harsh environments such as salt spray, dust, high temperature and high humidity, and ensure its service life in harsh environments.

A.

True

B.

False

Full Access
Question # 86

Cabinets (racks) arranged in a row, whose length exceeds the channel between the two channels should be added. , there should be channels at both ends: when the distance between the two channels exceeds

A.

6m, 15m

B.

6m, 20m

C.

8m, 15m

D.

8m, 20m

Full Access
Question # 87

What kind of circuit breaker is used in the sub-circuit of PDU8000 precision power distribution cabinet: /

A.

Molded case circuit breaker

B.

Miniature circuit breakers

C.

Frame circuit breaker

D.

isolating switch

Full Access
Question # 88

What is the minimum outdoor ambient temperature that the FusionModule800 air conditioner can support? ()

A.

-20℃

B.

-40℃

C.

0℃

Full Access
Question # 89

Huawei iManager NetEco6000 can be accessed by Huawei's () system

A.

XXX

B.

esight

C.

XXXX

Full Access
Question # 90

What is the seismic rating of the IT cabinet of FusionModule2000?

A.

8

B.

9

C.

7

Full Access
Question # 91

The cabinet width of Fusionmodule2000 is 600mm and 800mm ( )

A.

True

B.

False

Full Access
Question # 92

The integrated UPS is equipped with a lightning protection module ( )

A.

True

B.

False

Full Access
Question # 93

The static load of the FusionModule2000 cabinet can support 1800KG, which is the highest in the industry.

A.

True

B.

False

Full Access
Question # 94

The integrated UPS/integrated power distribution cabinet/precision power distribution cabinet of FusionModule2000 can detect the temperature of branch terminals through NTC probes.

This function is optional and unique to Huawei.

A.

True

B.

False

Full Access
Question # 95

The main circuit of the PDU8000 precision power distribution cabinet supports the monitoring of voltage harmonics and current harmonics.

A.

True

B.

False

Full Access
Question # 96

The basic principles of refrigeration of air-cooled and water-cooled air conditioners are the same

A.

True

B.

False

Full Access
Question # 97

Huawei air-cooled air conditioners (35kw and 46kw) - one indoor unit corresponds to one outdoor unit ( )

A.

True

B.

False

Full Access