H13-624_V5.5 Questions and Answers

Question # 6

If a performance Issue occurs in Huawei flash storage, an engineer can perform optimization operations according to the storage performance optimization process. Which of the following statements is false about the performance optimization process?

A.

In the information collection phase, the engineer needs to collect basic information about applications and data, such as the impact of application configurations on data, data size, and read/write ratio.

B.

In the test and application phase, the engineer needs to test the configurations to check whether the optimization objective is achieved. If yes, the engineer can put the system into use.

C.

In the optimization analysis phase, the engineer needs to specify the performance optimization objective, find out the performance bottleneck, and identify the parts that play a key role in Improving the system performance.

D.

In the optimization operation phase, the engineer needs to deploy DR for the service system, and needs to modify multiple configuration at a time during the optimization configuration.

Full Access
Question # 7

In Huawei flash storage. If you want to apply the HyperCDP feature to a LUN, you are advised to reserve 5% to 10% of the LUN capacity in the storage pool to which the I UN belongs for storing HyperCDP object data, and configure a protection capacity threshold for the storage pool to stop creating HyperCDP objects or even automatically delete HyperCDP objects when the storage pool capacity is insufficient.

A.

TRUE

B.

FALSE

Full Access
Question # 8

An industry customer has purchased several Huawei flash storage devices for service deployment. An engineer wants to configure the HyperSnap feature on the storage devices. However, during the configuration, the engineer discovers that snapshots cannot be created for an existing protection group. The possible cause is that the storage pool where the source LUNs in the protection group reside has no available capacity.

A.

TRUE

B.

FALSE

Full Access
Question # 9

Before configuring services for Huawei flash storage, you need to Initialize the system. Which statement about the initialization is false?

A.

You must change the IP addresses of the management network port and maintenance network port using the command-line interface (CLt) before applying for and activating a license.

B.

During security configuration management, read-only users have only the access permission to the storage device, that is, they can only perform query operations.

C.

When the TCP+SSl/TLS protocols are used for Syslog alarm notification, you need to set the certificate verification mode to improve the security of storage system logs.

D.

During the wizard-based initialization, you need to configure basic information, such as device information, device time, and licenses.

Full Access
Question # 10

The_____feature provided by the OceanStor Pacific series storage system supports OPS and bandwidth upper limit control based on namespaces, accounts, and client IP addresses.

Full Access
Question # 11

A financial customer purchases Huawei OceanStor Pacific 9950 for service deployment. During a routine inspection, an engineer finds that a main storage disk of the device is faulty and uses SmartKit to replace it. Which of the following statements is true about replacing the disk?

A.

When removing the disk, the engineer needs to remove it from its connector, wait at least 60 seconds, and then remove the disk from the chassis.

B.

Before using SmartKit to replace the disk, the engineer needs to complete the pre-processing as prompted. After that, the engineer can continue the subsequent operations.

C.

The duration from removing the main storage disk to installing a normal one on the node cannot exceed 10 minutes. Otherwise, heat dissipation of the storage device will be affected.

D.

The interval between removing the faulty disk and inserting a normal one is at least 10 seconds. Otherwise, the disk may be damaged.

Full Access
Question # 12

A school has purchased two Huawei OceanStor Pacific series storage devices for service deployment. An engineer wants to configure the distributed parallel client (DPC) on the storage devices. Which of the following statements is false about the engineer's configuration?

A.

If upper-layer services require high data security, the engineer needs to set the storage pool type to "Self-encrypting" when creating a converged storage pool.

B.

Before creating a converged storage pool, the engineer must enable the file service for nodes on DeviceManager.

C.

When creating a namespace, the engineer needs to select a security style and application type.

D.

When the storage network is a Remote Direct Memory Access over Converged Ethernet (RoCE) network, the engineer can run the "systemctl stop lldpad.service" command to disable the lldpad service.

Full Access
Question # 13

A financial customer purchases a Huawei OceanStor Pacific 9950 storage device for service deployment. Engineers have configured basic block storage services on the device. During an O&M management process, an engineer needs to modify the attributes of a storage pool. Which of the following attributes will not be modified?

A.

Hot spare policy of the storage pool

B.

Storage pool name

C.

Actual location of the storage pool

D.

Capacity alarm threshold

Full Access
Question # 14

During routine inspection, engineers find that several faults occur on Huawei all-flash storage and need to rectify the faults. Which of the following is not a basic troubleshooting principle for storage systems?

A.

Analyze network alarms before NE alarms.

B.

Analyze general alarms before specific alarms.

C.

Analyze alarms of higher severities before those of lower severities.

D.

Analyze external factors before internal factors.

Full Access
Question # 15

The service system needs to be backed up before performance optimization b performed on Huawei flash storage, and up to two optimization configurations can be changed at a time.

A.

TRUE

B.

FALSE

Full Access
Question # 16

When deploying a Huawei converged storage system, engineer A uses the UltraPath software. Which of the following statements are false about the load balancing algorithms of UltraPath?

A.

The min-queue-depth algorithm refers to the minimum queue depth algorithm. UltraPath is configured with this algorithm by default.

B.

Round robin is a min-task algorithm and can be used in scenarios where service I/O model data blocks delivered by the host are large.

C.

The min-task algorithm is a round robin algorithm and can be used in scenarios where the service I/O models delivered by the host have little difference.

D.

The algorithms fall into three types: min-queue-depth, round-robin, and min-task.

Full Access
Question # 17

During routine O&M, if an engineer finds that the system disk and some interface modules of a flash storage device are faulty, the engineer can directly remove and replace the faulty parts.

A.

TRUE

B.

FALSE

Full Access
Question # 18

Huawel OceanStor Pacific series storage supports the volume- or snapshot-based clone feature. Which of the following statements Is false about this feature?

A.

Small storage space occupation: A clone generated by the storage system is not a full physical data copy, which does not occupy large storage space.

B.

Quick generation: The storage system can generate a clone within several seconds to obtain the consistent copy of the source volume data.

C.

Lossless performance: Based on the ROW mechanism, the done write performance is equivalent to the source volume write performance.

D.

Cascading: Clones can be created based on clone volumes or snapshots of clone volumes in the storage system. A maximum of 64 cascading levels are supported.

Full Access
Question # 19

In Huawei flash storage, the administrator rote has full control permissions on storage devices. The administrator can power on, power off, and restart devices and create users of different roles.

A.

TRUE

B.

FALSE

Full Access
Question # 20

Assume an industry customer purchased several Huawei flash storage devices for service deployment. During routine management, an engineer found that the host bus adapter (HBA) driver version of the host is outdated and the number of concurrent HBAs was insufficient. As a result, the latency on the host differs greatly from that on the storage side. Which of the following measures can the engineer take to optimize performance?

A.

Use the management software provided by the HBA vendor to query and modify the number of concurrent HBAs.

B.

Upgrade the HBA driver to the latest version.

C.

Change the load balancing algorithm of the multipathing software to min-task.

D.

Change the cache prefetch policy to constant prefetch.

Full Access
Question # 21

The performance of a storage system can be measured by multiple indicators. In application scenarios where the I/O size is greater than or equal to 64 KB, the ________ performance indicator is the main concern for storage performance.

Full Access
Question # 22

In Huawei flash storage, the integrated I/O stack of SAN and NAS can be divided into the storage pool layer, space management layer, and data service layer. Which of the following are performance concerns of the space management layer?

A.

Cache hit ratio of hot metadata

B.

CPU usage of metadata background management

C.

Whether failover is enabled for protocol receiving threads

D.

Hit ratio of the prefetch algorithm

Full Access
Question # 23

A financial customer purchases a Huawei flash storage device for subsequent service deployment. During storage configuration, an administrator finds that LUNs mapped to an application server cannot be detected on the application server. Which of the following are possible causes of this exception?

A.

The storage pool is faulty.

B.

In HP-UX, the application server does not have a LUN mapping whose host LUN ID is 0.

C.

In UNIX or Linux, a device node file is lost.

D.

The serial port connection parameters are incorrectly set.

Full Access
Question # 24

An Internet customer has deployed a remote replication environment based on multiple flash storage devices. During actual service running, the customer discovers that there are multiple running statuses for a remote replication pair. Which of the following statements is true about the running status of a pair?

A.

After a pair is disconnected, if the pair is deleted from the primary or secondary site, which causes configuration inconsistency between the primary and secondary sites, the pair running status changes to "To be recovered."

B.

When the pair running status is "Split," the pair relationship between the primary and secondary LUNs is interrupted (not manually).

C.

When the pair running status is "Normal," data synchronization between the primary and secondary LUNs is complete.

D.

When the pair running status is "To be synchronized," the pair relationship between the primary and secondary LUNs must be manually disconnected to meet the service requirements of a single LUN.

Full Access
Question # 25

During routine management of Huawei flash storage, an engineer can use the "show license_active" command to query information about activated licenses.

A.

TRUE

B.

FALSE

Full Access
Question # 26

In OceanStor Pacific series storage systems, if a node or disk is faulty, data reconstruction in the disk pool can be automatically performed after 15 minutes.

A.

TRUE

B.

FALSE

Full Access
Question # 27

Huawei Ocean Protect Appliance adopts the key technology of CPU core grouping and intelligent scheduling, which is widely used by customers in many industries. Which of the following is the advantage of this technology?

A.

The scheduler can distribute jobs to other cores based on the service load status, implementing load balancing.

B.

When this technology is used to carry different services, some cores are overloaded, resulting in high latency.

C.

This technology implements physical and logical isolation of resources, reducing latency.

D.

The system can prefetch data and metadata from all LUNs, improving the cache hit ratio.

Full Access
Question # 28

Assume a financial customer purchased multiple Huawei OceanStor Dorado 18000 storage devices to carry service data. A Fibre Channel link exception occurred in the storage environment. Which of the following are possible causes for this exception?

A.

When a switch network is used, the configured rate of the Fibre Channel host port does not match that of the switch.

B.

The optical fiber is poorly connected or faulty.

C.

The optical module rate of host ports does not match that of front-end storage ports.

D.

The IP address of the service network port on the application server is incorrectly set.

Full Access
Question # 29

Which statements are false about software Installation of Huawei OceanStor Pacific series storage systems?

A.

To install the Distributed Parallel Client (DPC), the switch configuration is required before the installation regardless of whether the low level design (LLD)- or wizard-based installation mode is selected.

B.

To interconnect with FusionCompute during block service installation, storage and compute nodes must be deployed in converged mode, and the management nodes must be deployed in the virtualization environment.

C.

To interconnect with Huawei Cloud Stack during block service installation, storage and compute nodes must be deployed in converged mode, and the management nodes must be deployed in the virtualization environment.

D.

To install the file service in the standard protocol scenario, the switch configuration is not required throughout the entire installation process.

Full Access
Question # 30

Routine management on Huawei flash storage systems involves power-on and power-off. Which of the following statements is false about power-on and power-off?

A.

Before powering on the storage system, you need to ensure that all expansion cables are correctly connected. The storage system may work improperly if the connection mode of expansion cables is adjusted after the storage system is powered on.

B.

If none of the controller enclosures in the cluster are powered on, you can log in to the BMC system using the external management IP address of the BMC and run the power-on command to power on all the controller enclosures.

C.

To power on the storage system after an emergency power-off, you need to press the power button on the controller enclosure.

D.

For Huawei OceanStor Dorado 8000 storage, after a controller enclosure is powered on, its cascaded disk enclosures will be automatically powered on.

Full Access
Question # 31

A financial customer has purchased several Huawei OceanStor Dorado series storage devices for mission-critical service deployment. SmartMigration is configured to migrate services from a source LUN to a target LUN without interrupting host services. Which of the following statements about this feature is false?

A.

The implementation of a SmartMigration task between heterogeneous storage systems depends on the LUN takeover function provided by SmartVirtualization.

B.

When configuring this feature, you must plan the capacities of the source and target LUNs. The capacity of the target LUN must be greater than or equal to that of the source LUN.

C.

When configuring this feature, you cannot use a LUN that has been mapped to an application server as the target LUN of a SmartMigration task.

D.

The higher the migration rate, the better the host service performance is. Therefore, the highest migration rate can be used when the host service load is heavy.

Full Access