How to troubleshooting whether there is impact performance of failure hard disk in storage system
(slow)?
Which of the following statements of remote replication functions of array is correct?
Host side report the failure of "IO error or IO timeout", which of the following aspects can
eliminate storage side issues? (Select three Answers)
S5000 configure cache strategy, if use the write back mirroring.Because the mirror operation requires the interaction between two controllers, and the transmission of the datA. Therefore the overall performance is worse than write back mirroring.
LUN copy in storage array do not support copy a source of LUN to two goal LUN at the same time
For storage arrays products, What may cause the failure of roll back the snapshot? (Select three Answers)
The following which do not belong to the methods to improve the reliability of the data stored?
In the process of storage array implementing incremental LUN copy, the host can't read and write the target LUN.
Remote copy link between array according to transport protocol is divided into which several? (Select three Answers)
Striping depth change under random write performance rule of RAID5, which of the following is right?
For the storage array products, which of the following reasons will cause full amount LUN copy fault? (Select 3 Answers)
Which of the following description of storage system performance tuning is correct?
LUN copy S5000 incremental must interrupt host operations of reading and writing for the data of S5000 source LUN
what are the main difference between optical fiber topology FC-AL and FC-SW? (Select three
Answers)
Wide port definitions about SAS transmission medium, which the following statements are wrong?
With Linux, a disk output is as follows.
# fdisk -l
Disk /dev/sd 80.0 GB, 80026361856 bytes
255 heads, 63 sectors/track, 9729 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes
Device Boot Start End Blocks Id System
/dev/sdb1 * 1 2805 16386300 83 Linux
/dev/sdb2 2806 9729 55617030 5 Extended
/dev/sdb5 2806 3825 8193118+ 83 Linux
/dev/sdb6 3826 5100 10241406 83 Linux
/dev/sdb7 5101 5198 787153+ 82 Linux swap / Solaris
/dev/sdb8 5199 6657 11719386 83 Linux
/dev/sdb9 6658 7751 8787523+ 83 Linux
/dev/sdb10 7752 9729 15888253+ 83 Linux
Which of the following opinions are correct?
Which are the advantages of the optical switching topology relative to point-to-point and the arbitration ring? (Select 3 Answers)
Before configuring the remote replication, need to set up the physical link connection between the local array and the remote array.A controller of this side array can only connect A controller of the remote array, not be able to connect to B controller of the remote array.
Under Solaris system, when configuration multipath, what command need to activate and boot the STMS function in all port?
SAN storage system fault diagnosis, through ISM log can't judge fault, which log file can through
the further analysis system ? (Select three Answers)
Asynchronous remote replication in configure storage array need to configure silence perioD.
Add target under the solaris system, the command of IP address: iscsiadm add discovery-address
The management mode of ISM integrated storage management software for storage array is the in-band management modE.
what the limited number of add LUN from synchronous remote replication in storage array?
For alarm information analysis method, through the analysis of the alarm, the site can locate the exact location of the fault or reason, can also cooperate with other method to locate the cause of the problem with the alarm system is perfect, engineers can collect system alarms ID number, process library (document or IT) by XX fault, query the fault solution.
A control box of S5500 configured eight FC 300G and eight SATA 1T hard drives.Five FC 300G hard drives made RAID group 0, Five SATA 1TB hard drives made RAID group 1.Now, want to configure global hot spare disk for storage, in this case, how to configure it?
SAS domain is composed of SAS Expander and SAS terminal equipment, and connect through the SAS bus.
For storage array products, which may cause the failure of Incremental LUN copy?(Select 2 Answers)
Specify IP address ranges: according to the specified device management network ports IP addresses found the device, "start IP address" and "end IP address" refers to find the equipment IP address start and end points.