H12-425 Questions and Answers

Note! Following H12-425 Exam is Retired now. Please select the alternative replacement for your Exam Certification. The new exam code is H12-425_V2.0

H12-425 Questions and Answers

Question # 6

The () convert RS485/CAN protocol to the TCP protocol.

A.

Skylight actuator

B.

Wifi Converter

C.

Smart ETH gateway

D.

ETH Converter

Full Access
Question # 7

Through the ECC800Web interface, what can users do?

A.

Real-time monitoring of device status

B.

Query version information

C.

Export historical data

D.

Software upgrade

Full Access
Question # 8

NetEco can’t send work orders to processors.

A.

TRUE

B.

FALSE

Full Access
Question # 9

Which components can be installed onto the guide rail?

A.

ETH converter

B.

Access actuator

C.

Skylight Actuator

D.

AC Actuator

Full Access
Question # 10

Backup time of battery depends on discharge current of battery.

A.

TRUE

B.

FALSE

Full Access
Question # 11

When two UPS5000-E share battery strings, the battery capacity of each UPS should be set to the total capacity of battery strings.

A.

TRUE

B.

FALSE

Full Access
Question # 12

NetCol5000-A25 kW uses as thermal expansion valve.

A.

TRUE

B.

FALSE

Full Access
Question # 13

Which are the high reliability features of NetCol5000-C?

A.

The internal pipes are wrapped with thermal insulation foam

B.

Condensate water can be drained by water pump or nature drain pipe.

C.

Internal cabling water pipe and electrical control part are deployed at return air side

D.

Water is

Full Access
Question # 14

For UPS battery installation, the installation tools are not require to insulate.

A.

TRUE

B.

FALSE

Full Access
Question # 15

When connecting UPS5000-E in parallel, the parallel cables are not required to connect in a loop.

A.

TRUE

B.

FALSE

Full Access
Question # 16

UPS2000-G-10K supports: Three phase Input, Three phase Output

A.

TRUE

B.

FALSE

Full Access
Question # 17

Which statements are incorrect about the integrated UPS5000-E-120k-HASBS?

A.

The number of batteries is adjustable

B.

Cables can be routed from the top

C.

The ATS does not support manual switching.

D.

The power statistics page displays capacity of each output branch

Full Access
Question # 18

What should be done if the humidifier cylinder needs to be removed and maintained?

A.

Disconnect the cables of the water supply valve and the water drain valve.

B.

Remove the components of the water drain trough and valve

C.

Remove and clean the water supply valve.

D.

Replace the hose that has become rigid and fragile and thoroughly clean

Full Access
Question # 19

On the NetEco WebUI, one modular can be bound to a maximum of ( ) ECC800(s).

A.

1

B.

2

C.

3

D.

4

Full Access
Question # 20

UPS5000-E can do () for battery.

A.

Float charging

B.

Capacity test

C.

Equalized charging

D.

Shallow discharge test

Full Access
Question # 21

UPS2000-G-20 kVA displays that the batteries status NA, the possible reason is ().

A.

Batteries are not connected.

B.

Batteries are undervoltage

C.

Batteries are connected properly

D.

The neutral wire of the batteries is not connected

Full Access
Question # 22

If the electrical devices need to be checked, maintained and repaired with powering on, warning notices or indication plates should be set around the electrical devices.

A.

TRUE

B.

FALSE

Full Access
Question # 23

The input voltage range of the UPS5000-E is () V.

A.

305-485

B.

140-490

C.

120-480

D.

138-485

Full Access
Question # 24

Which statement are correct about UPS5000-E.

A.

It is modular UPS

B.

The input voltage range is 138-485V

C.

The input frequency range is 40-70Hz.

D.

A maximum of two UPS can be connected in parallel

Full Access
Question # 25

When ECC800 detects that a device is connected, a communication interruption alarm will generate. The possible reasons are ().

A.

The power supply is abnormal

B.

The cable connection is loose

C.

The cable connection is in poor contact

D.

The communication module device is faulty.

Full Access
Question # 26

When the compressor of NetCol5000-A started for the first time, the crankcase heating tape needs to be pre-heated for the time ( ) hours.

A.

2

B.

6

C.

12

D.

24

Full Access
Question # 27

If UPS5000-E is ( ), setting wizard automatically starts after power-on.

A.

Powered on for the first time

B.

Powered on after power-off

C.

Powered on after factory settings are restored.

D.

Powered on after faults are rectified

Full Access
Question # 28

The color of sight glass should be ( ) if there is no water existing in refrigerant system.

A.

blue

B.

green

C.

yellow

D.

orange

Full Access
Question # 29

The cold/hot aisle containment systems can improve cooling efficiency and reduce power consumption.

A.

TRUE

B.

FALSE

Full Access
Question # 30

The UPS5000 anti-seismic kit is applicable to earthquake-prone ones. When earthquake occurs, it provide support for cabinets

A.

TRUE

B.

FALSE

Full Access
Question # 31

The report of the NetEco can be dislayed in different formats, such as bar chart.

A.

TRUE

B.

FALSE

Full Access
Question # 32

The rack environment unit collects the environment data of IT cabinets

A.

TRUE

B.

FALSE

Full Access
Question # 33

The UPS5000-S-400K uses a ( ) kVA power module.

A.

25

B.

30

C.

40

D.

50

Full Access
Question # 34

On the Current Alarm page of NetEco, filter criteria can’t set to search for the required alarms.

A.

TRUE

B.

FALSE

Full Access
Question # 35

NetCol500 outdoor unit needs neutral wire.

A.

TRUE

B.

FALSE

Full Access
Question # 36

NetEco can’t manage the data center facilities in different places.

A.

TRUE

B.

FALSE

Full Access