H20-923_V1.0 Questions and Answers

Question # 6

If a component runtime overdue alarm is generated for an air conditioner, you can clear the device running time on the "Maint > Performance Maintenance" screen.

A.

True

B.

False

Full Access
Question # 7

If the startup password authentication for a smart module is not complete, the ECC800-Pro WebUI and app cannot be used for commissioning.

A.

True

B.

False

Full Access
Question # 8

Which of the following statements are true about the industry trend of the data center cooling systems?

A.

Liquid cooling systems are widely used in high-density solutions.

B.

Cloud + AI – data centers enter a new energy-saving era.

C.

Evaporative cooling systems become the main solution for large data centers.

D.

Higher inlet and outlet water temperatures are the trend of large data center cooling.

Full Access
Question # 9

When a critical alarm is generated for the unit, the indicator on the LCD controller turns red and the buzzer beeps continuously.

A.

True

B.

False

Full Access
Question # 10

When tightening the screws (M16x50 mm) for the output power cables of lithium battery cabinets, what torque should be used to tighten and verify the screws?

A.

100 N·m

B.

60 N·m

C.

120 N·m

D.

80 N·m

Full Access
Question # 11

The frequency of power supply equipment can be 50 Hz, 60 Hz, or 70 Hz.

A.

True

B.

False

Full Access
Question # 12

Operators can view parameters and set parameters on the "User Settings" and "Comm Settings" menus.

A.

True

B.

False

Full Access
Question # 13

Which of the following can be used to start the inverter of the UPS5000-H?

A.

UPS WebUI

B.

ECC

C.

UPS LCD

D.

NetEco

Full Access
Question # 14

After replacing the fan, choose "Menu > _____ > Performance Maintenance" on the main screen to enter the "Performance Maintenance" screen and clear the accumulated runtime of the indoor fan.

A.

Alarms

B.

Settings

C.

Running

D.

Maint

Full Access
Question # 15

ECO mode is not recommended when the load is less than

A.

10%

B.

30%

C.

5%

D.

20%

Full Access
Question # 16

Which of the following are main components of Huawei indirect evaporative cooling system?

A.

Compressor

B.

Air filter

C.

Water pump

D.

Spray system

E.

Heat exchanger

F.

Fan

Full Access
Question # 17

In an in-room solution that adopts overhead air supply through air ducts, the net height of each floor must be greater than or equal to how many meters?

A.

4

B.

6

C.

5

D.

3

Full Access
Question # 18

The NetEco supports manual backup and automatic backup.

A.

True

B.

False

Full Access