Summer Sale - Special 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: 70dumps

D-PE-OE-01 Questions and Answers

Question # 6

After adding DIMMs on a PowerEdge R760, the server powers on, fans spin, but the system does not reach POST. The LCD shows no error. What two things should be done to resolve this Issue?

A.

Reseat memory

B.

Replace the system board

C.

Verify DIMM population

D.

Update the BIOS

E.

Clear SEL logs

Full Access
Question # 7

A PSU is blinking green on a PowerEdge R750 while there no issue reported in the iDRAC. What is the most likely cause?

A.

The firmware of the PSU is being updated

B.

This indicates a PSU mismatch

C.

A valid power source is connected to the PSU

D.

indicates an issue with the PSU

Full Access
Question # 8

After adding a GPU to a Dell PowerEdge server:

• The operating system does not detect the GPU.

• Lifecycle Controller (LCC) Diagnostics reports a POST failure.

• IDRAC System Event Log shows a GPU power-related error.

What action should be performed first for practical troubleshooting?

A.

Reset the iDRAC network configuration.

B.

Modify the BIOS Thermal Profile.

C.

Reinstall the GPU driver.

D.

Reseat the GPU in its PCIe slot.

Full Access
Question # 9

You plan to update several components (PERC, NIC, BIOS) on a PowerEdge R760. The customer requires a rollback option if compatibility Issues appear. Which two actions should you take to prepare for a rollback?

A.

Record all currently installed firmware versions

B.

Rely on automatic hardware rollback built into all PowerEdge models

C.

Validate that rollback is supported for the component being updated

D.

Download previous firmware versions beforehand

Full Access
Question # 10

You are performing a GPU firmware update using IDRAC. IDRAC Direct was used during the update. The update stalls and the GPU appear unresponsive. What is the most likely cause of the issue?

A.

The server needs a BIOS downgrade

B.

The USB management port interaction

C.

The iDRAC license expired during the update

D.

The GPU is incompatible with the server OS

Full Access
Question # 11

A Dell PowerEdge R750 shows a sudden reduction in usable capacity on a RAID 6 virtual disk after replacing a failed drive with a larger one. The OS and iDRAC both report the VD as “Ready’" and “Optimal" but usable capacity remains unchanged. What is the cause of this behavior?

A.

The drive was added as a dedicated hot spare instead of a member disk

B.

The virtual disk remains limited by the smallest disk

C.

The rebuild failed and the virtual disk is using reduced capacity mode

D.

The virtual disk automatically expanded but the OS has not refreshed

Full Access
Question # 12

A customer wants to deploy security compliance at hardware level using TPM hashing algorithm. Which hashing algorithm meets the requirements of the customer?

A.

SHA-256

B.

MD5

C.

SHA-1

D.

AES-256

Full Access
Question # 13

An engineer needs to install an OS that is not supported by the Lifecycle Controller on a Dell PowerEdge server. Since the OS Deployment menu cannot be used, the engineer plans to proceed with a manual installation. Which two factors should be considered in this situation?

A.

Appropriate drivers based on storage configuration must be applied.

B.

Required drivers are manually managed during installation.

C.

Hardware compatibility with the OS must be verified before installation.

D.

Firmware and driver version compatibility is checked after installation.

Full Access
Question # 14

A company operates a Dell PowerEdge server configured with a RAID 10 virtual disk that hosts critical databases services. Monitoring tools indicate that the virtual disk usage has reached 95% of total capacity. The server provides 24/7 mission-critical services, so downtime must be minimized or completely avoided. Currently, the server has only one empty drive bay remaining. What should the operations team consider first to safely plan the expansion of the RAID 10 virtual disk?

A.

Check the RAID controller's capabilities, available drive bays, and whether expansion is supported.

B.

Replace the RAID controller with the latest model to guarantee maximum performance, then add the new disk.

C.

Add the new disk, trigger a rebuild of the RAID, and wait until the rebuild is complete before using the expanded capacity.

D.

Add the new disk and immediately perform Online Capacity Expansion through iDRAC.

Full Access
Question # 15

A new Dell customer is ordering servers that have very specific firmware dependencies. Any replaced parts of the same type must match the replaced original part identically. The procedure must be as simple as possible with minimal risk. What action should a technician take to accomplish this goal?

A.

Install and configure a repository manager

B.

Enable the Match Firmware of Replaced Part setting in BIOS

C.

Configure servers to access the remote firmware repository

D.

Enable the Collect System Inventory On Restart attribute

Full Access